In many locations from chemistry laboratories to industrial services, so as to guarantee the protection of life and property in opposition to a potential fire hazard, extinguishing systems are used along with detection and alarm techniques. xp2i can additionally be extraordinarily necessary that the extinguishing systems installed may be triggered by the fireplace extinguishing control panel, so as to remove a potential hearth with early intervention.
In order to fulfill these wants, and with 35 years of sectoral information and experience, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel operating in accordance with the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the distant efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing course of to be started manually and remotely; and
to ensure that the extinguishing process could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced utilizing surface-mount expertise and are aimed at making the automation of the extinguishing system and fireplace and fuel detection system excellent.
Image copyright: Mavili
Mavili Elektronik develops its products by all the time contemplating the needs of the installation. In instances that require the mixing of the extinguishing system with the clever addressable fire detection system, it supplies options by way of the monitoring modules that even have a ‘supervised’ option.
Supervised monitoring modules play an essential function in controlling the continuity of the cable connection between the loop and the extinguishing system. เกจ์วัดความดัน to detect a potential open or brief circuit within the wiring between the contact monitoring modules and the peripheral methods can cause disruption of the triggering, with doubtlessly crucial penalties. For this purpose, when choosing monitoring modules, it ought to be taken into consideration that they have supervised options.
Image copyright: Mavili
Since Maxlogic clever addressable fire detection and alarm management panels are constantly speaking with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to observe conditions such as open circuits and quick circuits which will occur in the system. Many duties can be carried out within the hearth extinguishing installation, such because the management and monitoring of all valves that may interrupt the circulate of water, water flow alarm switches, strain swap, and electric or diesel fire pumps.
By including two contact monitoring modules to 2 separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to regulate errors and the opposite to regulate the fire situation, monitoring and control of the extinguishing system through an intelligent addressable fire detection and alarm system can be performed successfully.
For more information, go to www.mavili.com.tr/en