Cleaning of submersible pressure transmitters or level probes

If the specific pressure sensor design of the submersible pressure transmitter or level probe is selected to measure the filling levels, this can indicate that the probe is used under environmental requirements which may cause failure of common level sensors.
The most adverse conditions such as soiled media, abrasive ingredients and sludge when found in wastewater treatment plants, brackish and wastewater tanks or even digester towers, impose special requirements on the look of a submersible pressure transmitter. One of many requirements on a submersible pressure transmitter is to have the lowest possible susceptibility to contamination or build-up of the pressure sensor by optimizing its design. Because of this , the typical design of a pressure transmitter with narrow pressure ports isn’t used within level probes because it would have a tendency to clog such applications.
Despicable of the submersible pressure transmitter and its pressurised sensor diaphragm is optimised to experience suprisingly low susceptibility to contamination. However, continuous operation in soiled media may lead to sticking of dirt particles on the stainless diaphragm. To obtain the highest accuracy and fastest response times in case of level change, the thickness of this stainless steel diaphragm is already minimised ex factory to just a few microns. Therefore, cleaning of the diaphragm should be carried out with caution. Always stay away from Big or edged tools. It is also strongly advised never to use the popular screwdrivers or pens.
If cleaning of the sensor diaphragm is essential, then rinse it utilizing a weak water jet or clean it carefully using compressed air. Damage of the diaphragm because of denting or notching, even if it appears to be purely superficial, results in significant losses in the accuracy of level measurement. Deformation of the diaphragm often shifts the zero point of the pressure measurement in the inner electronic measurement system and additionally distorts the output signal linearisation which has been adjusted ex works to the undamaged diaphragm. Thus, the submersible pressure transmitter with damaged diaphragm generates falsified measurement of the existing filling level and, therefore, cannot be considered a trusted measuring instrument any more. Thus, complete replacement of the damaged instrument is completely necessary.
Please find more info with this topic on our information platform ? Defiance ?

Leave a Comment